missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Pierce™ LC-MS/MS System Suitability Standard (7 x 5 mixture)

Product Code. 16261851 Shop All Thermo Scientific Products
Click to view available options
Concentration:
0.5 pmol/μL
5 pmol/μL
Unit Size:
100µL
25µL
This item is not returnable. View return policy
This item is not returnable. View return policy

Pierce LC-MS/MS System Suitability Standard (7 x 5 mixture) contains seven HeavyPeptide AQUA Ultimate peptides provided at five dilutions distinguished by differential isotopic labeling to assess sensitivity and dynamic range of LC-MS/MS systems.

The Pierce LC-MS/MS System Suitability Standard (7 x 5 mixture) contains seven PRTC HeavyPeptide AQUA Ultimate peptides in five isotopologue versions for the generation of seven standard curves to assess sensitivity and dynamic range of LC-MS/MS systems.

The Pierce LC-MS/MS System Suitability Standard (7 x 5 mix) contains 7 of 15 peptides from the Pierce Peptide Retention Time Calibration Mixture (Cat. No. 88320). Each of the seven peptides has five versions (amino acids labeled with 0, 1, 2, 3, or 4 heavy isotopes) at five distinct concentrations. The 7 x 5 mix can be used with Skyline software to assess dynamic range, linearity, and lower limit of quantitation (LLOQ).

The Pierce LC-MS/MS System Suitability Standard (7 x 5 mixture) is:
High quality—contains five sets of seven HeavyPeptide AQUA Ultimate peptides, each distinguishable through unique isotopologue labeling
Optimized—enables scheduling of MS acquisition windows for improved quantification and increased multiplexing
Quantitative—assesses dynamic range of instrument and instrument sensitivity
Predictive—enables assessment of chromatography and MS instrument performance

Applications:
• Optimization of LC & MS parameters
• Standard for data-dependent acquisition (DDA)
• Standard for targeted MS (e.g., parallel-reaction monitoring (PRM)
• Identification of total peptide elution window
• Assessment dynamic range of nano or capillary flow LC-MS/MS systems

TRUSTED_SUSTAINABILITY

Specifications

Description Pierce™ LC-MS/MS System Suitability Standard (7 x 5 mixture) (0.5 pmol/μL)
Product Line Pierce™
Shipping Condition Dry Ice
Concentration 0.5 pmol/μL
For Use With (Equipment) Mass Spectrometer
Type LC-MS/MS System Standard
Quantity 25 μL
Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.